Reference catalogs · instrument mechanism
Concrete Mix Design Calculator (ACI Method, Simplified) mechanism
The inspectable method record for Concrete Mix Design Calculator (ACI Method, Simplified), kept separate from implementation and qualification.
Model scope
NEEDS_REVIEW because the stated instrument inputs and formula description are insufficient to implement a reproducible ACI 211.1 design. The vectors use clearly identified representative ACI-style table fragments and added material-property assumptions solely to make the arithmetic independently computable. Production implementation must identify the exact ACI edition/table revision, include all required aggregate and air inputs, define interpolation and exposure-governing rules, apply moisture corrections, and check applicable ACI code limits.
- The specification does not provide the actual ACI 211.1 lookup-table values or define how to select between strength-based and exposure-based maximum water-cement ratios.
- Water-cement ratio is not determined solely by target f'c; the governing value must be the lower of the strength requirement and the applicable exposure limit, with applicable minimum cement and durability requirements also checked.
- A complete ACI absolute-volume design requires aggregate specific gravities, coarse-aggregate dry-rodded unit weight, fine-aggregate fineness modulus, entrapped or entrained air, and aggregate moisture/absorption corrections. These are absent from the declared inputs.
- A yield check based only on summed masses is not valid. Yield must be checked by absolute component volumes, and the fine aggregate quantity must be solved from the absolute-volume equation.
- The simplified method does not specify interpolation rules for target strength, slump, or aggregate size when values fall between table entries.
- ACI 211.1 mix design is not validated merely by a yield check; trial batches and measured slump, air, strength, and unit weight are required before structural use.
Units and conventions
- Test vectors use SI quantities per m³ unless explicitly marked yd³.
- Target compressive strength f'c is entered in psi because the referenced ACI strength table is conventionally tabulated in psi.
- Slump is entered in inches and nominal maximum aggregate size in inches.
- Water and aggregate quantities are SSD-basis quantities; no aggregate moisture or absorption correction is applied in these vectors.
- Cement specific gravity is assumed to be 3.15, coarse aggregate specific gravity 2.65, and fine aggregate specific gravity 2.60.
- Entrapped air is assumed to be 2.0% by volume for these non-air-entrained examples.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"target_fc_psi": 4000,
"slump_in": "3-4",
"max_aggregate_size_in": 0.75,
"exposure_class": "mild",
"fine_aggregate_fineness_modulus": 2.8,
"coarse_aggregate_dry_rodded_unit_weight_kg_m3": 1600,
"output_unit": "kg/m3"
},
"expected_outputs": {
"water_kg_m3": 205,
"water_cement_ratio": 0.48,
"cement_kg_m3": 427.083,
"coarse_aggregate_kg_m3": 992,
"fine_aggregate_kg_m3": 689.204,
"absolute_volume_yield_m3": 1
},
"reference_data": {
"water_kg_m3_for_non_air_entrained_concrete": {
"slump_in": "3-4",
"max_aggregate_size_in": 0.75,
"value": 205,
"source_convention": "ACI 211.1 water-content table, commonly reproduced standard value"
},
"strength_water_cement_ratio": {
"target_fc_psi": 4000,
"value": 0.48,
"source_convention": "ACI 211.1 strength-to-w/c table, commonly reproduced standard value"
},
"exposure_max_water_cement_ratio": {
"exposure_class": "mild",
"value": 0.6,
"source_convention": "ACI 318 durability convention, mild exposure maximum w/c"
},
"coarse_aggregate_volume_fraction": {
"fine_aggregate_fineness_modulus": 2.8,
"max_aggregate_size_in": 0.75,
"value": 0.62,
"source_convention": "ACI 211.1 coarse-aggregate volume table, commonly reproduced standard value"
},
"coarse_aggregate_dry_rodded_unit_weight_kg_m3": 1600,
"source_convention_for_coarse_unit_weight": "Widely tabulated standard value for normal-weight aggregate",
"cement_specific_gravity": 3.15,
"source_convention_for_cement_specific_gravity": "Widely tabulated standard value",
"coarse_aggregate_specific_gravity": 2.65,
"source_convention_for_coarse_specific_gravity": "Widely tabulated standard value",
"fine_aggregate_specific_gravity": 2.6,
"source_convention_for_fine_specific_gravity": "Widely tabulated standard value",
"entrapped_air_fraction": 0.02,
"source_convention_for_air_fraction": "ACI 211.1 non-air-entrained normal-weight concrete design assumption"
},
"working": "1. Strength w/c = 0.48. Exposure limit = 0.60, so governing w/c = min(0.48, 0.60) = 0.48. 2. Cement = water/(w/c) = 205/0.48 = 427.083 kg/m³. 3. Coarse aggregate = 0.62 × 1600 = 992 kg/m³. 4. Cement volume = 427.083/(3.15×1000) = 0.135582 m³. Water volume = 205/1000 = 0.205000 m³. Coarse aggregate volume = 992/(2.65×1000) = 0.374340 m³. Air volume = 0.020000 m³. 5. Fine aggregate volume = 1.000000 − 0.135582 − 0.205000 − 0.374340 − 0.020000 = 0.265078 m³. Fine aggregate mass = 0.265078×2.60×1000 = 689.204 kg/m³. 6. Absolute-volume yield = 0.135582 + 0.205000 + 0.374340 + 0.265078 + 0.020000 = 1.000000 m³."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The calculator breaks on a zero maximum aggregate size because the required table lookup is undefined, and it is vulnerable to materially different behavior when target-strength units are entered without an explicit psi-versus-kPa convention.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.