Reference catalogs · instrument mechanism
Ksp Solubility Calculator mechanism
The inspectable method record for Ksp Solubility Calculator, kept separate from implementation and qualification.
Model scope
The four vectors are valid under the stated concentration-based, ideal-dilute assumptions. Implementation should add common-ion identity, molar mass or chemical formula, temperature/database metadata, validation of physical roots, and explicit activity-versus-concentration labeling.
- The core concentration-based relation Ksp=[A]^x[B]^y is standard for a salt dissolving as A_xB_y(s) ⇌ xA + yB, but the common-ion formula is underspecified: the instrument must identify whether the added ion is A or B and apply the corresponding stoichiometric substitution.
- The advertised g/L output requires a molar mass, but molar mass or chemical formula is absent from the listed inputs.
- The specification does not state whether Ksp values use concentrations or activities. The stated equation is valid as a concentration approximation for sufficiently dilute solutions, not universally as a thermodynamic activity expression.
- For higher stoichiometries, the physical nonnegative root must be selected; polynomial equations can have multiple mathematical roots. The inverse calculation from s to Ksp is not explicitly defined, although it follows from the stated equation.
Units and conventions
- Ksp is dimensionless or treated numerically in the conventional concentration-standard-state convention.
- All dissolved concentrations and common-ion concentrations are in mol/L (M); any mM input must be converted to M before calculation.
- The solid phase activity is 1, temperature is fixed, and activity-coefficient effects are neglected.
- g/L is calculated as s in mol/L multiplied by molar mass in g/mol.
- The listed molar masses are an additional required input when g/L is requested.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"salt": "AgCl",
"x": 1,
"y": 1,
"Ksp": 1.8e-10,
"common_ion": null,
"molar_mass_g_per_mol": 143.321
},
"expected_outputs": {
"molar_solubility_s_M": 0.00001341640786,
"solubility_g_per_L": 0.001922852991
},
"working": "AgCl ⇌ Ag+ + Cl−, so [Ag+]=s and [Cl−]=s. Ksp=s^2. s=sqrt(1.8×10^−10)=sqrt(1.8)×10^−5=1.341640786×10^−5 M. g/L=s×M=1.341640786×10^−5×143.321=1.922852991×10^−3 g/L."
}Failure boundary
BREAK_CLAIMED · SELF_FLAGGED
The negative-Ksp vector must be rejected because the real solubility formula has a negative square-root argument. The specification also leaves unit interpretation and the distinction between free-ion and total common-ion concentration insufficiently explicit, creating possible incorrect results if the interface accepts an unqualified numeric common-ion value.