Reference catalogs · instrument mechanism
Linear Equation Solver mechanism
The inspectable method record for Linear Equation Solver, kept separate from implementation and qualification.
Model scope
The stated algorithms are mathematically standard, but the instrument needs explicit domain, dimensional-unit, parser, singular-system, and numerical-tolerance policies before receiving an unconditional PASS.
- Substitution and elimination are standard correct methods for linear equations and systems.
- Cramer's rule is correct only for square systems with a nonzero determinant; the specification does not state how singular, dependent, or inconsistent systems are handled.
- The supported variable count, equation count, and coefficient-shape constraints are not explicitly defined for the claimed 2-3 equation systems.
- Free-text equation parsing is underspecified, including variable-name rules, implicit multiplication, signs, parentheses, malformed input, and nonlinear terms.
Units and conventions
- All terms added or equated within an equation must have compatible physical units.
- For ax+b=c, a, b, and c are assumed dimensionally compatible with x and the equation's result; if x has units, a generally carries result-units per x-unit.
- No unit conversion is performed unless explicitly implemented; coefficients and constants are otherwise treated as dimensionless numbers.
- All coefficients and constants are assumed to be finite real numbers unless complex or symbolic domains are explicitly supported.
Inspectable vector
One of 4 source-bound review vectors:
{
"inputs": {
"equation": {
"a": 3,
"b": -5,
"c": 10
},
"form": "a*x+b=c"
},
"expected_outputs": {
"solution_set": {
"x": "5"
},
"residual": "3*5-5-10=0",
"spot_checks": [
{
"at": {
"a": 3,
"b": -5,
"c": 10
},
"input_side": 5,
"answer_side": 5
},
{
"at": {
"a": 4,
"b": 7,
"c": 19
},
"input_side": 3,
"answer_side": 3
}
]
},
"reference_data": {
"method": "isolate x",
"formula": "x=(c-b)/a",
"domain_constraint": "a != 0"
},
"working": "3x-5=10; add 5 to both sides: 3x=15; divide by 3: x=15/3=5; residual: 3(5)-5-10=15-5-10=0. Numeric formula checks: (10-(-5))/3=15/3=5.00000000 and (19-7)/4=12/4=3.00000000."
}Failure boundary
- Division by zero occurs in the scalar solver when a=0; the cases 0*x+b=c must be classified as either no solution or infinitely many solutions.
- Cramer's rule must not be used when the determinant is zero; singular systems require rank-based classification into no solution or infinitely many solutions.
- A non-square coefficient matrix, underdetermined system, or overdetermined system needs an explicit solution-set policy.
- Floating-point arithmetic can misclassify nearly singular systems; determinant and residual tolerances must be specified.
- Free-text input can contain nonlinear expressions, contradictory variable names, omitted coefficients, or ambiguous syntax.
- The empty honest_label field should be populated to state supported domains, exact-versus-numeric behavior, singular-system behavior, and parser limitations.
Other records
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.jsonevidence-tranche8/tranche8-results.json